Posts

Rectifier Phase Shift Transformer

Image
Rectifier Phase Shift Transformer Phase-Shifting Rectifier Dry-type Transformer Feature: Waveform smoothing,low harmonic pollution, good heat disspatio Model: ZPSG Type Phase-Shifting Rectifier Dry-type Transformer Features :  Low harmonic pollution. good heat disspation.strong to withstand thermal shock.over-load capacity.low loss and noise. The rated capacity : 315—1600KVA Rated voltage : 6KV+5% or 10KV+5% It can be classified into several groups such as 9 secondary side, 12 secondary sides, 15 secondary sides and 24 secondary sides having various shifted phases,according to the capacity of the transformer The phase shifting angles is o °, 12°, 24°,36°,48°,or according to the requirements of the customers.

Modern Design Phase Shifting Rectifier Transformer

Image
Modern Design Phase Shifting Rectifier Transformer Performance characteristics 1, easy installation, demolition, covers an area of less, can be installed indoors, outside. 2, energy efficient, just consume a small amount of electricity, you can absorb a lot of heat in the air, the power consumption is only 1 / 3-1 / 4 of the heater. 3, special transformer environmental pollution: no any combustion and emissions, is a sustainable development of environmentally friendly products. 4, special transformer safe and reliable operation: the operation of the entire system without the traditional dryer (fuel, gas or electric heating) may exist flammable, explosive, poisoning, short circuit and other dangerous, is absolutely safe and reliable closed drying system. 5, special transformer long service life, low maintenance costs, is based on the traditional air-conditioning technology developed from mature technology, stable performance, safe and reliable operation, automatic operation-fre

Three Phase Shifted Rectifier Transformer

Image
Three Phase Shifted Rectifier Transformer Use environment 1. Elevation not exceeding 1000m; 2. Ambient temperature is not higher than +40 ° C, not lower than -20 ° C; 3. Air relative humidity is not more than 95% (+ 25 ° C); 4. There are methane mixed gas and coal dust, and there is a risk of explosion in place; 5. No strong bumps, vibrations and inclination with the vertical plane does not exceed 15 ° environment; 6. Where there is no corrosive gases and vapors of metals and insulating materials; 7. No dripping and watering place.

Phase Shift Rectifier Oil Type Power Transformer

Image
Phase Shift Rectifier Oil Type Power Transformer Advantages: a.The cancellation of oil conservator makes the transformer more convinient to use; b.The replacement of oil tube into corrugated tank makes the transformer easier to cool;               c.The physical property of corrugated tank increases the reliability of the transformer;                   d.The adoption of sanforizing makes sure the robustness of long distant transportation.

Hot sale Phase shift rectifier transformer

Image
Hot sale Phase shift rectifier transformer Specifications 3 Phase-shifting rectifier Dry-type Transformer Features: Waveform smoothing, low harmontic pollution, good heat dissipti Specifications: 3 phase-shifting rectifer Dry-type transformer(11KV) Waveform smoothing, low harmontic pollution, good heat dissiption, strong to withstand thermal shock, over-load capaci Phase-Shifting Rectifier Dry-type Transformer Feature: Waveform smoothing,low harmonic pollution, good heat disspatio Model: ZPSG Type Phase-Shifting Rectifier Dry-type Transformer Features: Low harmonic pollution. good heat disspation.strong to withstand thermal shock.over-load capacity.low loss and noise. The rated capacity: 315—1600KVA Rated voltage: 6KV+5% or 10KV+5% It can be classified into several groups such as 9 secondary side, 12 secondary sides, 15 secondary sides and 24 secondary sides having various shifted phases,according to the capacity of the transformer The phase shifting angles is o°, 12°, 24°,36°,48

Dry-type Transformer

Image
Dry-type Transformer Phase-Shifting Rectifier Dry-type Transformer Feature: Waveform smoothing,low harmonic pollution, good heat disspation Model: ZPSG Type Phase-Shifting Rectifier Dry-type Transformer Features:  Low harmonic pollution. good heat disspation.strong to withstand thermal shock.over-load capacity.low loss and noise. The rated capacity: 315—1600KVA Rated voltage: 6KV+5% or 10KV+5% It can be classified into several groups such as 9 secondary side, 12 secondary sides, 15 secondary sides and 24 secondary sides having various shifted phases,according to the capacity of the transformer The phase shifting angles is o°, 12°, 24°,36°,48°,or according to the requirements of the customers.